Lesson 03 / Calibration

Calibration & Levels

Remove the rig from the measurement. Establish absolute SPL. Protect headroom.

Purpose

Two calibrations: soundcard (interface loopback response) and microphone (mic/meter correction). Plus SPL calibration for absolute dB SPL and healthy levels to avoid clipping or noise.

Numbered Workflow

  1. Soundcard cal (analog mics/interfaces only): Loopback output → input with appropriate cable. In Preferences → Soundcard → Calibrate. Save file. This is sample-rate-specific. Do NOT use with USB mics (they have no soundcard in path).
  2. Mic cal: Load manufacturer's .txt cal file (freq, gain, optional phase). For USB mics with sensitivity line Sens Factor = ... REW can infer SPL without separate SPL cal. Analog mics use Sensitivity -12.34 dBFS line.
  3. SPL cal (if needed): Use external SPL meter or calibrator. Preferences → SPL Meter → Calibrate. C-weighted option available. For electronics, use FS sine Vrms.
  4. Check Levels: Generator → Pink noise → play through system. Adjust AV processor volume + sweep level to read ~75dB SPL on REW SPL Meter.
  5. Input gain: Adjust interface input to -30 to -12 dBFS RMS. Headroom indicator should be green, ideally 6–40dB. Mute monitoring to avoid feedback loop.
  6. Safety: Disable phantom power during loopback. Verify correct input channel. Recalibrate if you change input volume or sample rate.
Cal file format: frequency gain [phase] per line, e.g. 1000 0.0 0.0. REW limits cal boost to 20dB by default to avoid boosting noise floor — override only with reason.

Outputs & Interpretation

  • Mic/Meter Cal trace: Correction applied. Should be smooth; sharp kinks = bad cal file.
  • Soundcard Cal trace: Should be near-flat for good interface. Large deviations = check loopback cable/levels.
  • SPL Meter: Absolute SPL after cal. Overload indicator = clipping.
  • Headroom: Distance to FS. <6dB = risky, >40dB = noisy. Aim middle.

Worked Example — USB Mic at 75dB

Goal: Prepare UMIK-1 for subwoofer measurement at listening position.

  1. Load 90° cal file (mic pointing up for sub work). Verify Sens Factor line present → SPL cal not needed.
  2. Set AMS + REW to 48kHz/24-bit. No soundcard cal (USB mic).
  3. Check Levels → pink noise → adjust AVR to 75dB SPL, input to -18dBFS, headroom 22dB green.
  4. Save. Ready for sweep 10–300Hz.
Deeper Detail — Sensitivity & Validity

USB mic sensitivity: Factory Sens Factor encodes dBFS per Pascal. REW computes SPL directly. If missing, you must do SPL cal.

Sample-rate specificity: Soundcard cal is only valid at calibrated rate. Changing rate invalidates it.

Limit cal boost: Prevents REW from applying +30dB correction where mic rolls off — which would just amplify noise. Keep at 20dB unless measuring with known extension.

FS sine Vrms: For electronics, calibrate so 0dBFS sine = known Vrms at interface output.

Check Your Understanding

You change input gain on your interface after SPL cal to get more headroom. What must you do?