Purpose
Two calibrations: soundcard (interface loopback response) and microphone (mic/meter correction). Plus SPL calibration for absolute dB SPL and healthy levels to avoid clipping or noise.
Numbered Workflow
- Soundcard cal (analog mics/interfaces only): Loopback output → input with appropriate cable. In Preferences → Soundcard → Calibrate. Save file. This is sample-rate-specific. Do NOT use with USB mics (they have no soundcard in path).
- Mic cal: Load manufacturer's .txt cal file (freq, gain, optional phase). For USB mics with sensitivity line
Sens Factor = ...REW can infer SPL without separate SPL cal. Analog mics useSensitivity -12.34 dBFSline. - SPL cal (if needed): Use external SPL meter or calibrator. Preferences → SPL Meter → Calibrate. C-weighted option available. For electronics, use FS sine Vrms.
- Check Levels: Generator → Pink noise → play through system. Adjust AV processor volume + sweep level to read ~75dB SPL on REW SPL Meter.
- Input gain: Adjust interface input to -30 to -12 dBFS RMS. Headroom indicator should be green, ideally 6–40dB. Mute monitoring to avoid feedback loop.
- Safety: Disable phantom power during loopback. Verify correct input channel. Recalibrate if you change input volume or sample rate.
frequency gain [phase] per line, e.g. 1000 0.0 0.0. REW limits cal boost to 20dB by default to avoid boosting noise floor — override only with reason.
Outputs & Interpretation
- Mic/Meter Cal trace: Correction applied. Should be smooth; sharp kinks = bad cal file.
- Soundcard Cal trace: Should be near-flat for good interface. Large deviations = check loopback cable/levels.
- SPL Meter: Absolute SPL after cal. Overload indicator = clipping.
- Headroom: Distance to FS. <6dB = risky, >40dB = noisy. Aim middle.
Worked Example — USB Mic at 75dB
Goal: Prepare UMIK-1 for subwoofer measurement at listening position.
- Load 90° cal file (mic pointing up for sub work). Verify
Sens Factorline present → SPL cal not needed. - Set AMS + REW to 48kHz/24-bit. No soundcard cal (USB mic).
- Check Levels → pink noise → adjust AVR to 75dB SPL, input to -18dBFS, headroom 22dB green.
- Save. Ready for sweep 10–300Hz.
Deeper Detail — Sensitivity & Validity
USB mic sensitivity: Factory Sens Factor encodes dBFS per Pascal. REW computes SPL directly. If missing, you must do SPL cal.
Sample-rate specificity: Soundcard cal is only valid at calibrated rate. Changing rate invalidates it.
Limit cal boost: Prevents REW from applying +30dB correction where mic rolls off — which would just amplify noise. Keep at 20dB unless measuring with known extension.
FS sine Vrms: For electronics, calibrate so 0dBFS sine = known Vrms at interface output.
Check Your Understanding
You change input gain on your interface after SPL cal to get more headroom. What must you do?